Scope
- Engines
- All engines
- Roles
- Admin
- ClusterEye
- ClusterEye 1.6.50 and laterWritten from the product code
- The Thresholds section is open to the Admin role only; the server also requires admin rights to save thresholds and overrides.
- The node list comes from the monitored nodes; a node that is not listed has to be added to monitoring first.
When this guide helps
- I want a different CPU alarm threshold for one server
- how do I set a threshold for a single node
- a batch server raises a disk alarm every night, I only want to raise its threshold
- loosen an alarm for one database without changing the global threshold
- undo a per-node threshold override
- separate alarm threshold for one cluster
Steps
Step 1: Administration → Settings
DoOpen Administration → Settings → Alerting → Thresholds. In the scope switch of the 'Alarm thresholds' panel choose 'Node', then pick the server from the list ('Pick a node').
Look forThe scope switch: Global, Environment, Cluster, Node. The hint sentence next to it ('Values here apply to this node only; ...'). Nodes that already have their own values carry an 'own values' tag in the list. The table keeps only the alarms of the selected node's engine.
How to read itValues apply in this order: global, environment, cluster, node. A field you enter in the Node scope becomes that node's own value; fields you do not touch are inherited from the layer above and are drawn with a dashed outline (hovering shows 'From cluster ...' or 'From environment ...'). The Environment and Cluster options are disabled when no environment label or cluster exists; you set the environment label on the Clusters page. If several nodes need the same difference, the Cluster or Environment scope means less repetition than one override per node.
Step 2: Administration → Settings
DoPick the sub-tab for the topic (Host, Connections, Replication, Queries, Locking, Storage, Engine health ...) and edit 'Warning at' and 'Critical at' in the row of the alarm. If needed open the row arrow and look at the 'What these values would have done' preview (7 days / 14 days / 30 days).
Look forThe 'unsaved' tag on the row you edited; in the preview the 'Saved values', 'With your edits' and 'Actually recorded' counts, scoped to this node alone, and the 'Would open' list. In the Suggested column the suggestion drawn from this node's own 30-day baseline.
How to read itIf 'With your edits' is far below 'Saved values' you are loosening the alarm noticeably on this node; compare with 'Actually recorded' to judge whether that is real relief or a risk of missing the alarm. The Suggested value is computed from hourly averages and does not contain short spikes. 'Must last' and 'Recovery margin' are shared settings on the Behaviour tab; they are changed there, not in an alarm's own row.
Step 3: Administration → Settings
DoSave with 'Save' on the row or 'Save <alarm name>' in the editor. Then switch the scope back to 'Global' and open the arrow of the same alarm.
Look forAfter the save an 'own values' tag on the 'Alarm' column and 'This node has its own values for this alarm' in the editor. In the Global scope the same alarm's row carries a tag such as '1 node has own values' and the editor lists 'Own values below global' (node name and values); clicking a list entry opens that node's scope.
How to read itThis is how you confirm the override was actually saved and which nodes diverge from the global value. If you later change the global value, a node with its own value keeps it; only the fields it did not set follow the new global value. Check this list regularly so a later global change does not surprise you.
Step 4: Administration → Settings
DoTo remove an override go back to the Node scope, pick the node, open the alarm's arrow and press 'Use inherited values'.
Look forThe 'own values' tag disappearing, the values returning to the dashed (inherited) style and the '... uses the inherited values again' message.
How to read itThe node's own values for that alarm are removed and the node inherits from the layer above again. If the node has no own values left for any alarm, its override record is deleted altogether. The node's own values on other alarms are not affected.
Outcome
By the end, the warning and critical thresholds of the alarm are saved and verified for the chosen node, separately from the global values; 'Use inherited values' undoes it. ClusterEye saves the setting for you here; later evaluations use the new thresholds. For global thresholds and notification channels see the 'Setting alarm thresholds and notification channels' guide.
Related guides
Set up the Slack, Email and Teams channels in Settings, route alarms to channels with Alert Routing, and decide in Thresholds when each alarm warns or turns critical.
Incident responseOn the Alarms page prioritise active alarms, read an alarm's detail, acknowledge and own it, snooze it or silence it with a maintenance window when needed, and close it as resolved.