Scope
- Engines
- All engines
- Roles
- AdminDBAViewer
- ClusterEye
- ClusterEye 1.6.50 and laterWritten from the product code
- Viewing alarms and adding a note to an alarm is open to all monitoring roles (Admin, DBA, Viewer). Acknowledging, assigning, snoozing and resolving need the Admin or DBA role; creating and editing maintenance windows is also for those two roles only. A Viewer does not see these buttons or sees them disabled.
- Some drawer sections such as Query, Pattern and History fill only for the matching alarm type; 'Investigate with AI' in the 'AI Investigation' section needs the Admin or DBA role.
When this guide helps
- a critical alarm fired, where do I start
- how do I acknowledge an alarm and take ownership
- I want to silence an alarm temporarily
- stop alarms during planned maintenance
- how do I close many alarms at once
- why was this alarm triggered, where can I see it
- who is working on this alarm, who owns it
- an alarm fired, what should I do
Steps
Step 1: Observe → Alarms
DoOpen Observe → Alarms in the sidebar (the page title is 'Alarm Operations Center'). Look at the tile strip on top and click the 'Critical' or 'Major' tile to narrow the list to that severity.
Look forThe 'N active alerts · updated ...' line in the header. The tiles: Active (with the Opened / Resolved flow), Critical, Major, Warning, Info, Workflow (Unassigned, Unacknowledged, Acknowledged, Snoozed, Suppressed) and Response (MTTA, MTTR).
How to read itActive counts alarms that are not resolved, snoozed or suppressed by a maintenance window. In the Workflow tile 'Unassigned' and 'Unacknowledged' count active alarms with no owner or team and alarms nobody has acknowledged yet, respectively, and turn to the warning colour when above zero. MTTA is the mean time to acknowledge and MTTR the mean time to resolve; only alarms carrying both timestamps count. A second click on a tile removes the filter. The page refreshes every 30 s; use 'Refresh' to refresh at once.
Step 2: Observe → Alarms
DoPick the queue to work from the tabs (Active, Acknowledged, Snoozed, Resolved, All). In the filter panel on the left choose a view under 'Quick views', for example 'Unassigned' or 'My alerts'; use the 'Severity', 'Status', 'Owner', 'Team', 'Detection source', 'Engine', 'Host' and 'Database' filters or the search box ('Search alerts, hosts, databases, clusters…'). Set the time window with the 'Time range' picker.
Look forQuick views: My alerts, My team, Unassigned, Unacknowledged, Snoozed, Suppressed, 'Long running (>1h)', 'Recently resolved (24h)'. Table columns: Severity, Alert / Problem, Resource, Context, Duration, Owner, Status. Some rows are grouped under a 'Correlated incident #N' header.
How to read itThe Detection source filter separates where an alarm came from: Threshold, Anomaly or Intelligence. 'Suppressed' is not a standing tab; alarms silenced by a maintenance window are reached through 'Suppressed' in the Workflow tile, 'Quick views' or 'Suppressed by window' in the filter panel (the tab is then added to the tab bar). A 'Correlated incident #N' header means related alarms are grouped as one incident; 'Why grouped' opens why they were merged and every alarm in the incident. With many related alarms, start from the incident drawer instead of going one by one.
- If you see: The alarm is left over from last night and you want to see what happened over time → What happened last night: reading incidents and root cause on the Timeline
Step 3: Observe → Alarms
DoClick the title of the most important alarm; the alarm drawer opens on the right. Read its sections in order.
Look for'Current state' (Current value or Anomaly score, Source, Occurrences, First seen, Last seen, Duration, Host, Engine, Database, Cluster), 'Ownership', 'Why was this triggered?', and where present 'Query', 'Pattern', 'History', 'AI Investigation', 'Notifications' and 'Activity'. A link such as 'Open Deadlock & Blocking Center' when it fits the alarm.
How to read itFor Intelligence-sourced alarms the value is shown as an 'Anomaly score' (/ 100), not a measurement. 'Why was this triggered?' describes the trigger only from fields the system actually recorded: which value crossed which threshold or expected range, and how many consecutive evaluations it lasted. 'Pattern' and 'History' show earlier recurrences from the same source and previously recorded resolutions; they say what was recorded in the past, not what is wrong now. 'Notifications' lists which channels the notification went to and 'Activity' who did what. The link takes you to the matching analysis screen, where you look for the root cause.
Step 4: Observe → Alarms
DoTake the alarm on: acknowledge it with the main button of the drawer or row menu ('Acknowledge' on a New alarm); in the dialog add an optional note and choose 'Mute notifications for' (1 hour ... 7 days, default 24 hours). Then own it with 'Assign to me' or 'Assign…', start work with 'Start investigation', and use 'Mark mitigated' once a fix is applied.
Look forThe lifecycle in the Status column: New, Acknowledged, Investigating, Mitigated, Snoozed, Suppressed, Resolved. In 'Ownership' the Owner, Team, 'Acknowledged by' and 'Acknowledged at'. A 'Take ownership' link on an alarm owned by someone else. A new entry in 'Activity'.
How to read itAcknowledging records that someone has seen the alarm and is aware; it stays active until the condition clears or an operator resolves it. 'Mute notifications for' only silences notifications for the chosen period. These actions need Admin or DBA; a Viewer can only add a note with 'Add note'. The drawer shows only the actions that fit the current state (for example only a note on a resolved alarm).
Step 5: Observe → Alarms
DoIf the cause is temporary, choose 'Snooze': 15 minutes, 30 minutes, 1 hour, 4 hours, 'Until tomorrow 09:00' or 'Custom…', a 'Reason' (Maintenance, Known issue, Deployment, False positive, Temporary workaround, Other) and 'Snooze'. For planned work use the 'Maintenance windows' button in the page header and, on the page it opens, create a window with 'New window' (Name, Scope, Starts, Ends, Timezone).
Look forA snoozed alarm shows 'Snoozed' and its end time in Status, with the 'Resume now' and 'Extend snooze' actions. On the maintenance windows page the 'Active now', 'Scheduled', 'Completed' and 'Cancelled' tiles and the Active / Upcoming / Past tabs; the Name, Scope, Start, End, Timezone, 'Created by' and Status columns. Scope options: Everything, 'Host / node', Cluster, Engine, Database.
How to read itSnooze does not resolve the alarm: it hides it from the Active view and, if the condition persists, it returns by itself when the time is up. A maintenance window silences notifications for alarms in its scope, and those alarms become 'Suppressed'; ending the window with 'End now' returns matching alarms to the Active view at once. Creating and changing maintenance windows is a separate permission (Admin and DBA); without it the buttons are disabled with the tip 'Your role cannot manage maintenance windows'.
Step 6: Observe → Alarms
DoOnce the problem is fixed choose 'Resolve' in the drawer or row menu; fill 'Resolution', 'Root cause area' and the note, then confirm with 'Resolve'. For many alarms tick the rows and use Acknowledge, Assign, Snooze or Resolve in the 'Bulk actions' bar that appears. For a whole correlated incident use 'Resolve incident…' from the incident drawer.
Look forIn the resolve dialog the 'What resolved it? (optional)' and 'Which area? (optional)' fields. In the bulk bar '<N> alerts selected' and an (eligible/selected) count on each button. The resolved alarm appears in the 'Resolved' tab, with who resolved it and how in the 'Resolved' field.
How to read itResolve marks the alarm as resolved by an operator; if the condition returns later it opens as a new alarm. Resolution and Root cause area are optional, but filling them makes them show up as 'Previously recorded resolutions' in the 'History' section of later alarms with the same pattern. In a bulk action the number on a button shows how many of the selection the action can apply to; alarms it cannot apply to (for example already acknowledged ones) are skipped. If the condition clears by itself the alarm is resolved 'automatically (condition cleared)'.
Step 7: Observe → Alarms
DoWhile you are on another page, follow incoming alarms from the bell icon in the top bar: click the bell, look at the Unread / Active / Recent tabs, and use 'Investigate' (or 'Acknowledge') on a toast card.
Look forIn the bell panel the 'Notifications' header, the severity and lifecycle status of each entry, and the 'View Alarm Operations Center' link at the bottom. On a toast card the title, the resource line (host · engine · cluster · database) and the 'Investigate' / 'Acknowledge' buttons; when several alarms are merged into one card, 'View N alerts'.
How to read itBy default new critical and major alarms appear as toasts, while warning and info alarms only collect in the bell panel; snoozed or maintenance-suppressed alarms produce no toast. A notification being read in the bell does not mean it is acknowledged; that needs 'Acknowledge'.
Outcome
By the end an alarm is acknowledged, owned, snoozed or silenced by a maintenance window where needed, and closed with 'Resolve' once fixed. The actions in this guide change the alarm record inside ClusterEye (status, owner, note); they do not change the database itself. To find the root cause follow the link in the drawer to the analysis screen; to reduce how many alarms arrive see the 'Setting alarm thresholds and notification channels' guide.
Related guides
Set up the Slack, Email and Teams channels in Settings, route alarms to channels with Alert Routing, and decide in Thresholds when each alarm warns or turns critical.
Incident responseOn the Timeline page narrow the last 24 hours by severity, read an incident's root-cause summary and story, drill into raw events and, if needed, get a plain-language account with AI Explain.
Getting startedGo from the Database Estate Health page on Home to Clusters and the AI Database Doctor to read the overall state of your estate, the problems that need attention and the monitoring gaps.